CGEO-MICRO-MCU Datalogger can perform automatic measurement, data processing, chart creation, and abnormal measurement value alarming for various engineering safety monitoring instruments. It integrates user management, measurement management, data management, and communication management, providing great convenience and strong support for automated measurement and data processing in engineering safety.
Concrete curing
Earthquake early detection
Dams and bridges
Land slide
Mining exploration
Pipelines monitoring
Railways
Rock falls
Tunnels
The datalogger consumes minimal power from either a 12 VDC or mains power source. Power supply options are flexible depending on the site and can include mains, solar cell, and wind generation.
Universal–compatible with majority of the commercially available sensors
Programmable–customised software deployment forchanging and challenging requirements
High input Impedance–ensure accurate sensor readings
Programmable analogue output – for connection to SCADA or control application
Capable to test sensor integrity through audible frequency
Model | CGEO-Micro-MCU | ||||
Channels | 6、8、16、24、32、40 | ||||
Signal | Vibrating Wire | Differential Resistance | Standard Analog | Linear Potentiometer | RS485 |
Range | Frequency 400Hz~5000Hz | Resistance Ratio 0.8000~1.2000 | Voltage -10V ~ + 10V | 0~10KΩ | |
Accuracy | Frequency 0.1Hz | Resistance Ratio 0.0001 | Voltage 0.02%F.S. | Resistance Ratio 0.0001 | |
Resolution | Frequency ±0.1Hz | Resistance Ratio 0.00001 | Voltage <0.1mV | Resistance Ratio 0.00001 | |
Measuring time per channel | Vibrating Wire <3s, Differential Resistance <4s | Clock accuracy | ±1 minute/month | ||
Other sensors | Determined by the stabilization time of the visual sensor | Operating temperature | -30℃ ~+ 70℃ | ||
Communication method | LAN/WIFI/RS485/GPRS/ Fiber Optic | Storage temperature | -40℃ ~+ 85℃ | ||
| Consumption | Standby <0.5W, Operating <3W | Data storage capacity | Customizable | ||
Power Suppl | DC 12~24V / AC 110~220V; Battery 12V 7Ah maintenance-free battery | Dimensions | 24-channel and above Enclosure Dimensions: | ||
Interface | Ethernet, WIFI, RS485, USB, etc. | Enclosure protection grade | IP65 | ||

Copy product links